Basic Info.
Certification
CE, UL, CCC, CB, FCC
Product Description
S-100W switching power supply:
Low price and high reliability105° C output capacitorAC input power suitable for the worldHight efficiency and low operation temperatureSoft-start current can reduce the AC input impact effecticlyWith Short-circuit and owwerload protectionCompact size, light weight100% full-load burning testInstalled with EMI filter, minimum wave.
Product Description:
Model / Specification
S-100-3
S-100-5
S-100-7-5
S-100-12
S-100-15
S-100-24
S-100-27
S-100-48
DC output voltage
3V
5V
7.5V
12V
15V
24V
27V
48V
Output voltage error (Note2)
± 2%
± 2%
± 1%
± 1%
± 1%
± 1%
± 1%
± 1%
Rated output current
20A
20A
13.6A
8.5A
6.7A
4.5A
3.7A
2A
Output current rage
0-20A
0-20A
0-13.6A
0-8.5A
0-6.7A
0-4.5A
0-3.7A
0-2A
Wave and noise(Note3)
100mVp-p
100mVp-p
100mVp-p
100mVp-p
100mVp-p
100mVp-p
100mVp-p
100mVp-p
Inlet stability(Note4)
± 0.5%
± 0.5%
± 0.5%
± 0.3%
± 0.3%
± 0.2%
± 0.2%
± 0.2%
Load stability(Note5)
± 0.5%
± 0.5%
± 0.5%
± 0.3%
± 0.3%
± 0.2%
± 0.2%
± 0.2%
DC output power
60W
100W
102W
102W
100.5W
108W
99.9W
96W
Efficiency
70%
78%
80%
81%
81%
84%
84%
84%
Adjustable range for DC voltage
2.85-3.3V
4.75-5.5V
6.75-8.25V
10.8-13.2V
13.5-16.5V
21.6-26.4V
26-32V
43.2-52.8V
AC input voltage range
85~132VAC/180~264VACselected by switch47~63Hz; 255-370VDC
Input current
2.4A/115V 1.2A/230V
AC impulse current
Cold-start current 30A/115V 60A/230V
Leakage current
<1mA/240VAC
Overload protection
Over-voltage protection
...
High-temperature protection
...
Temperature coefficient
± 0.03%° C(0~50° C)
Setup rise hold up time
200ms, 100ms, 30ms
Vibration
10~500Hz, 2G 10min. /1cycle, Period for 60min, Each axes
Withstand voltage
Input and output interval: 1.5KVAC, Input and enclosure: 1.5KVAC, Output and enclosure: 0.5KVAC
Isolation resistance
Input and output interval, Input and enclosure, Output and enclosure: 0500VAC/100M Ohms
Working temperature and humidity
-10~+60, 20%~90%RH
Store temperature and humidity
-20~+85, 10%~95RH
Overall dimension
199*98*38mm
Weight
0.5Kgs
Safety standards
Meet UL1012
EMC standards
...
Note: 1. The testing condition for the parameter above is: 230VAC input, rated load, 25° C 70%Rh, Humidity
2. Error, include the setting error, line stability and load stability. (Note: 5)
3. Wave test: Adopting"A12"double wire for 20MHz, and 0.1uF&uF capacitor short-circuit for interrupting
4. Inlet voltage stability test: When is over load, the lowest voltage of inlet is representative to the highest voltage.
5. Load stability test: The load is from 0% to 100%, others 60%.
6. C2, 3, 11must be knocked down.
Address:
Qianjin Industrial Zone, Wengyang Town, Yueqing, Wenzhou, Zhejiang, China
Business Type:
Manufacturer/Factory
Business Range:
Electrical & Electronics
Management System Certification:
ISO 9000, ISO 9001
Company Introduction:
Zhejiang Yowa Electric Co., Ltd.Located in WengYang Industrial Zone, Wenzhou, ZheJiang, China.Our company mainly produce contactor, AC Contactor, circuit breaker, MCB, MCCB, RRCB, Soft starter, transformer and other low-voltage electrical products.All of our products comply with international quality standards.