Basic Info.
Usage
Light, Industry, Construction, Digital Products, Vehicle
Product Description
1. Small volume, light weight
2.100% full load burn-in test
3. Soft start circuit, limiting AC surge current
4. Width input voltage range
5. Short circuit, overload, over voltage protection
6. High efficiency, low working temperature, long lifespan
Switching Power Supply Technical Data
Model Specification
S-35-5
S-35-12
S-35-15
S-35-24
DC output voltage
5V
12V
15V
24V
Output voltage error(Note, 2)
± 2%
± 1%
± 1%
± 1%
Rated output current
7A
3A
2.4A
1.5A
Output current rage
0-7A
0-3A
0-2.4A
0-1.5A
Wave and noise(Note, 3)
75mVp-p
100mVp-p
100mVp-p
100mVp-p
Inlet stability(Note, 4)
± 0.5%
± 0.5%
± 0.5%
± 0.5%
Load stablity (Note, 5)
± 1%
± 0.5%
± 0.5%
± 0.5%
DC output power
35W
36W
36W
36W
Efficiency
70%
76%
78%
78%
Adjustable range for DC voltage
+10, -5%
+10%
+10%
+10%
AC input voltage range85-132VAC/170-264VACSelected by switch47-63Hz, 240-370VDC
Input current0.5A/115V 0.25A/230A
AC INnrush current
Cold-start current15A/115V 30A/230V
Leakage current<0.5mA/240VAC
Overload proctection105%-150%Type: Foldback: Current limiting reset: Auto recovery
Over-voltage protection...
High-temperature protection...
Temperature coefficient± 0.03%/(0-50)
Setup rise hold up time200ms, 100ms, 30ms
Vibration10-500HZ, 2G 10min, /1cycle, Period for60min, Each axes
Withstand voltageInput and output internal, 1.5KVAC, Input and enclosure, 1.5KVAC, Output and enclosure0.5KVAC
Isolation resistanceInput and output internal: Input and enclosure, Output and enclosure, 500VDC/100MΩ
Working temperature and humidity-10~+60(Refer to output derating curve), 20%~90%RH
Store temperature and humidity-20° C~+85° C. 10%~95%RH
Overall dimension129× 98× 38mm
Weight0.4Kgs
Safety standardsMeet UL 1012 requirement(Not apply for the mark)
EMC standardsMeet FCC part15J Conduction classB
Note 1. The testing condition for the paramenter above is, 230VAC input, rated load, 25 70% RH. Humidity. 2. Error. Include the setting error, line stability and load stability. (Note: 5). 3. Wave test: Adopting "A12"double wire for 20MHz, and 0.1UF&47UF capacitor short-circuit for interrupting. 4. Inlet voltage stability test: When is over load, the lowest voltage of inlet is up to the highest voltage. 5. Load stability test: The load is from 0% to 100%.
Address:
Qianjin Industrial Zone, Wengyang Town, Yueqing, Wenzhou, Zhejiang, China
Business Type:
Manufacturer/Factory
Business Range:
Electrical & Electronics
Management System Certification:
ISO 9000, ISO 9001
Company Introduction:
Zhejiang Yowa Electric Co., Ltd.Located in WengYang Industrial Zone, Wenzhou, ZheJiang, China.Our company mainly produce contactor, AC Contactor, circuit breaker, MCB, MCCB, RRCB, Soft starter, transformer and other low-voltage electrical products.All of our products comply with international quality standards.